Hit Enter to Search
Flowgas TMS 500

Flowgas TMS 500

Consumption sensor for compressed air and gases Screw-on pipe diameters up to DN300

 

Inquire now
  • Mobile compressed air measurement

  • Flow measurement of process gases and nitrogen generators


Application description
  • Depth scale for accurate installation
  • Easy installation under pressure
  • Inner diameter adjustable via keys
  • Consumption counter resettable
  • High accuracy
  • Negligible small pressure loss
Application description

The affordable consumption counter TMS 500 works according to the proven calorimetric measuring principle. A heated sensor is cooled by the gas flowing around him. The flow-dependent cooling is utilized as a measuring scale while the degree of cooling is directly dependent on the passing air or gas mass. An additional pressure and temperature compensation is therefore not necessary.

For larger pipe diameters from DN 50 to DN 300 the consumption sensors TMS 500 are available. In addition to pressure air, other gases can be measured e.g. Nitrogen, oxygen, CO2.

The installation of the TMS 500 via a standard G 1/2 "ball valve under pressure. The retaining ring prevents the probe is thrown out uncontrollably during installation and removal by the operating pressure. For installation in different pipe diameters the TMS 400 can be associated with different probe lengths. The exact positioning of the sensor in the center of the pipe is possible via an engraved depth scale.

Technichal data

Measured variables: flow (mass flow), total consumption, speed

Reference standard: 1000 mbar, 20 ° C according to DIN 1945, ISO 1217 (standard factory setting); other standard conditions at the factory.

Measuring principle: calorimetric measurement

Sensor: PT45, Pt1000

Measuring medium: air, Nitrogen, argon, nitrous oxide, CO2, oxygen, natural gas

Operating temperature: -30 ... 110 ° C probe tube; -30 ... 80 ° C Case

Operating pressure: up to 50 bar

Power supply: 12 to 30 VDC

Power consumption: max. 80 mA at 24 VDC

Analog output: 4 ... 20 mA, max. Load <500 ohms

Accuracy: ± 3% v.M .; With measurement range of ± 2% V. M. (Option via 5 point ISO precision calibration); These data are only valid in connection with the measuring section

Accuracy: ± 4% v.M .; Without measurement range of ± 3% V. M. (Option via 5 point ISO precision calibration); These data are only valid if the entered correctly inside diameter

Display: 128 x 64 pixel backlit; Measured flow value max. 6 digits, counter max. to 1999999999, l or m³ then jumps back to 0

Units: standard factory setting m³ / h, m³; selectable via software or button on the display: m³ / h, m³ / min, l / min, l / s, kg / s, kg / min kg / h, cfm, m / s

Thread: G 1/2 "