  • IDEM’s coded non-contact safety interlocks are designed to conform to IEC 60947-5-3 and be used as directed by ISO12100, ISO14121 and ISO14119.

  • They feature solid state technology, providing a high tolerance to shock, vibration and tampering.

  • The hall effect operation means the contacts are volt free with a switching capability of 0.2A dc.

  • They are suitable for hinged, sliding or removable guard applications and can connect to most safety relays to provide a higher level of functional safety.


Features
Housing/Fixing: Hygienic mounting, slim line body
Material: Mirror Polish (Ra4), 316 stainless steel ideal for exposure to chemical cleaning agents
Contacts: Up to 3 N/C or 2 N/C + 1 N/O
Sensing Distance: Wide 14mm operation
Ingress Protection: IP67 and IP69K
Operating Temperature: -25C to 105C
Connection: Pre-Wired or M12 8-pole Quick Connect
Indication: Single Colour LED – Green when door closed
Special Features
Suitable for Splash Zones in accordance with EHEDG guidelines