Advantages |
Application description |
The compact thermometer Thermocont® TK is used to measure temperatures from -50 ... 150 ° C. Locations are for example Pipelines or containers.
The ACS is available Thermocont TK on standard process connections, but also for use in hygienic areas.
Rapid installation with M12 connector with IP66/67, small and compact design in stainless steel, high quality, reliability and accuracy characteristics of this sensor. Besides the standard version with 4 .. 20 mA output and selectable ranges, can also direct Pt100 4-wire output to work (optional). Various process connections, sensor diameter, length or other versions with reduced peak, or with neck allow a flexible use for virtually all process conditions.
Technische Daten |
Sensorelement: Pt100 Klasse A nach IEC 751
Ausgang: Analog 4...20mA, 20...4mA oder Pt-100 4-Leiter
Versorgungsspannung: 10...35V DC
Einschaltverzögerung: 2s
Genauigkeit gesamt: 0,1K oder 0,08%
Langzeitstabilität: <0,1K/Jahr
Betriebstemperatur: -50...+150°C
Umgebungstemperatur: -40...+85°C
Lagertemperatur: -40...+100°C
EMV-Verträglichkeit: Störfestigkeit und Störaussendung nach EN 61 326-1 (IEC 1326)